0769-83101070
18128032987
  • Technical Specification
Constant temperature and humidity/liquid circulation testing equipment
机台名称 恒温恒湿/液体循环检测设备
Detection object metal
Test content Metal acid and alkali resistance test
Overall dimensions 2060(W)*1870(L)*1940(L)
weight 1200KG
Effective itinerary Lifting table 180mm
Targeting Positioning of the hanging basket support column
Operation method Manually pick and place products, automatically control temperature and humidity
Measured product size range Can be customized according to needs
Main parameters of the detection system 1. South Korea imported LCD temperature and humidity controller (SSR output), high precision and high stability.
2. PT100 thermocouple sensor imported from Japan to ensure temperature accuracy.
3. PID automatic calculation, controller display and setting.
4. The heating is the inner air heating method, the temperature rises quickly, and the temperature distribution is even. 
5. Non-standard air conditioning system, flexibly adjust the temperature and humidity in the box.
6. There are two independent containers in the box, which can hold different test liquids respectively.
Temperature uniformity ±2℃
Humidity uniformity ±3%
Temperature fluctuation ±0.3℃
Humidity fluctuation ±0.5%
Temperature control accuracy ±0.1℃
Main configuration a. Stainless steel shell/liner, automatic lifting movement mechanism, product fixed fixture.
b. Touch screen temperature and humidity control system.
c. Under-voltage, over-voltage, over-current, over-temperature protection, lightning protection device.
d. Temperature and humidity sensor, heating and cooling module, atomization module.
Use environment a. Temperature: 25℃±2℃.
b. Humidity: 65%±3%.
c. Vibration: There is no strong vibration around.
d. Power supply:
    Constant temperature and humidity equipment: 380V AC, 50HZ/60HZ; (three-phase five-wire); 2. Power: <9KW; 3. The power supply is directly connected to the power supply circuit breaker; 4. The power supply needs to be grounded.
    Liquid circulation equipment: 380V AC, 50HZ/60HZ; (three-phase five-wire); 2. Power: <20KW; 3. The power supply is directly connected to the power supply circuit breaker; 4. The power supply needs to be grounded.
e. The way of product feeding and discharging:
   manually open and close the door to pick and place the product and visually check OK/NG
* The detection accuracy that can be achieved due to different materials of products and different surface treatment processes will vary, and the actual measurement results shall prevail.